|
Drop Point Apparatus
Drop Point Apparatus Specification
- Temperature
- Ambient to 300C
- Application
- Determination of drop point of lubricating greases
- Power Supply
- 230V AC, 50Hz
- Test Range
- Up to 300C (temperature drop point determination)
- Measuring Range
- Ambient to 300C
- Automation Grade
- Semi-automatic
- Display Type
- Digital LED display
- Port Size
- Suitable for standard test tubes
- Operating Voltage
- 230V AC
- Features
- Digital control, Stainless steel body, Uniform heating, Adjustable temperature
- Interface Type
- Analog / digital controls
- Frequency
- 50 Hz
- Equipment Type
- Drop Point Apparatus
- Accuracy
- 1C
- Max Height
- 40 cm approx.
- Mounting Type
- Bench-top
- Resolution
- 0.1C
- Number of Specimens
- Single specimen per test
- Gas Pressure
- Adjustable; uses LPG gas for heating
- Specimen Size
- Standard grease cup size - as per ASTM D566/D2265
- Response Time
- Instantaneous digital readout
- Usage
- Laboratory testing of grease
- Capacity
- One sample at a time
- Machine Weight
- 8 kg approx.
- Test Speed
- Manual operation
- Control Mode
- Digital temperature controller
- Heater Type
- Gas heating with regulated flame
- Test Method Compliance
- ASTM D566, ASTM D2265
- Thermometer Range
- 0C to 300C
- Cooling System
- Removable glass beaker setup for water bath
- Material of Construction
- Powder-coated mild steel, heat-resistant glass
- Heating Time
- Approximately 10-15 minutes to max temp
- Safety Features
- Over-temperature protection, insulated body
- Grease Cup Material
- Brass
Drop Point Apparatus Trade Information
- Minimum Order Quantity
- 10 Units
- Payment Terms
- Cash in Advance (CID)
- Supply Ability
- 50 Units Per Month
- Delivery Time
- 10 Days
- Main Domestic Market
- All India
About Drop Point Apparatus
Versatile Application Areas of Drop Point Apparatus
Designed primarily for laboratory analysis, the Drop Point Apparatus is ideal for research and quality control labs testing lubricating greases. Its spectacular capability extends to petrochemical, manufacturing, automotive, and service industries where grease performance is critical. The bench-top, semi-automatic operation makes it an essential device for routine analysis and product development, accommodating standard test specimens as per ASTM specifications. Use this apparatus for any scenario where determining accurate drop points is paramount.
Packaging, Valuation, and Supply Estimates
Packaging of the Drop Point Apparatus is handled with care to ensure safe transit, typically incorporating shockproof insulation and robust sealing. Our supply network extends across India, with major deliveries servicing industrial hubs and metropolitan labs. Delivery time is estimated at 5-10 working days post-order, with careful valuation conducted to guarantee product integrity. Add to Cart and benefit from efficient, reliable dispatch, with each apparatus thoroughly checked before shipment to ensure you receive the highest quality equipment.
FAQ's of Drop Point Apparatus:
Q: How is the Drop Point Apparatus used in laboratory testing?
A: The Drop Point Apparatus is utilized to determine the temperature at which lubricating greases transition from a semi-solid to liquid state. This process involves precisely heating a standard grease cup specimen and monitoring the drop point using digital controls and instant LED readouts.Q: What unique features enhance the apparatus's performance?
A: Key features include digital temperature control, over-temperature protection, adjustable LPG gas heating, and an insulated body for safety. The glass beaker water bath ensures effective cooling, while analog/digital controls offer ease of operation and a remarkable accuracy of 1C.Q: When should this apparatus be chosen for grease testing?
A: This apparatus is ideal when precise, compliant drop point determination is required, especially for samples needing adherence to ASTM D566 or D2265 standards. It's suitable for both routine quality checks and product research.Q: Where is the Drop Point Apparatus most commonly supplied?
A: Most supply and delivery occur across India's primary research, industrial, and petrochemical laboratories, where reliable and accurate grease testing is essential for ongoing manufacturing and quality assurance.Q: What benefits does its digital LED display offer during usage?
A: The digital LED display provides instantaneous and clear temperature readings, enhancing precision and enabling efficient monitoring throughout the entire testing process.Q: How long does it take to reach maximum operating temperature?
A: The apparatus achieves a maximum temperature of 300C in approximately 10-15 minutes, allowing for swift and effective laboratory throughput.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Testing Equipment Category
Mechanical Grease Worker
Minimum Order Quantity : 10 Units
Application : Preparation and shearing of lubricating grease for penetration tests
Temperature : Ambient (540C)
Power Supply : 220V AC, 50 Hz
Humidity : Ambient (1090% RH)
Control Mode : Manual lever drive
Pensky Martens Flash Point
Minimum Order Quantity : 10 Units
Application : Petroleum Product Flash Point Testing
Temperature : Ambient, Measurement upto 370C
Power Supply : 230V AC, 50Hz
Humidity : Up to 80% RH (noncondensing)
Control Mode : Manual
Reid Vapoor Pressure
Minimum Order Quantity : 10 Units
Application : Determination of vapour pressure of petroleum products
Temperature : Ambient to 100C
Power Supply : 230 V AC, 50 Hz
Humidity : Standard Laboratory Conditions
Control Mode : Manual
Reid Vapour Pressure Apparatus
Minimum Order Quantity : 10 Units
Application : Determination of vapour pressure of petroleum products
Temperature : Test Bath Range: Ambient to 60C (with thermometer)
Power Supply : 230V AC, 50 Hz
Humidity : Up to 80% RH noncondensing
Control Mode : Manual with Pressure Gauge
![]() |
PETRO-DIESEL INSTRUMENTS COMPANY
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |





Send Inquiry



